Air supply Unit
Air Supply Unit is intended to positively pressurize the Spray Painting Booth. At Treat Air we integrate the ASU as per the actual requirement of paint shop and site conditions. ASU would resist entry of dust inside the paint shop area especially paint booths and offer operator comfort with air filtration as per requirement.
Capacity
- 50000 CMH to 350000 CMH
Types / Salient Features of Treat Air ASUs
- Dry filtration without water.
- Wet type with spray nozzles water washer system for high capacity.
- Wet type with Celldek media
- SS/GI/PVC mist eliminators for complete moisture removal
- VFD for motor speed variation, consequent capacity- Energy Savings.
- Maintenance facilities
- Double Skin Puff Panels to give better thermal /noise insulation.
Optional Features
- Heating by Electrical Heaters / Gas Burners- for Winter.
- Cooling (Air conditioning) by chiller.
- Air temperature and humidity control for sustained atmosphere inside the paint booth.